Technical Documentation

Product Data Sheets

Official technical documentation from our manufacturer partners — datasheets, installation guides, and system manuals for specifiers, engineers, and consultants.

Fire Alarm Systems

Notifier by Honeywell

Intelligent addressable and conventional panels — UL Listed, FM Approved.

📄

ONYX NFS2-640 Fire Alarm Panel

Mid-size intelligent panel — ONYX sensing, 640 character display, voice command

Notifier · UL · NFPA 72
📄

ONYX NFS2-3030 Fire Alarm Panel

Large-scale panel — 3,000+ devices, 10 SLC loops, NOTI-FIRE-NET compatible

Notifier · UL · FM
📄

INSPIRE Series — Networkable Life Safety

Scalable system with CLSS cloud and self-test UL-approved detectors

Notifier · CLSS · Self-Test
📄

SWIFT Wireless Mesh System

UL-approved Class A wireless fire detection — no cable installation required

Notifier · Wireless · UL
Detection Devices

Hochiki

ESP addressable and CDX conventional detection — EN 54 · LPCB · VdS approved.

📄

ESP Addressable Sensor Range

Optical smoke, heat, multi-criteria — ESP protocol, response under 1.5 sec

Hochiki · LPCB · EN 54
📄

CDX Conventional Detection Range

SOC-E3N smoke · DCD-AE3 heat · SPC-ET beam detector 5-100m

Hochiki · EN 54 · LPCB
📄

FIREbeam Beam Smoke Detector

Long-range beam detection up to 100m — 1,500m² coverage

Hochiki · EN 54-12
📄

Ekho Hybrid Wireless Detection

Wireless retrofit fire detection — ideal for heritage and listed buildings

Hochiki · Wireless · EN 54
Foam & Sprinkler Systems

Viking Corporation

FM Approved and UL Listed foam systems, sprinkler heads, and valves — NFPA 11 and 13.

📄

Foam System Technical Manual

Complete foam system manual — bladder tank, deluge, SFFF, proportioning

Viking · FM 5130 · NFPA 11
📄

Sprinkler Head Catalogue

Commercial, storage, ESFR, extended coverage, and special application heads

Viking · FM · UL · NFPA 13
📄

Deluge, Dry & Pre-Action Valves

Halar-coated valves for foam-water and water-only deluge systems

Viking · FM Approved
📄

SFFF Fluorine-Free Foam Systems

Zero PFOS/PFOA — biodegradable, FM approved, EN 13565-2 compliant

Viking · SFFF · FM
Clean Agent Suppression

SIEX & Kentec Electronics

FM-200, Novec 1230, CO₂ systems and suppression control panels.

📄

SIEX-HC Clean Agent System

FM-200 and Novec 1230 total flooding — up to 60 bar, FM and UL listed

SIEX · FM · UL · NFPA 2001
📄

SIEX CO₂ Suppression System

High and low pressure CO₂ for unoccupied industrial hazards

SIEX · NFPA 12
📄

Kentec Sigma / Taktis Control Panels

Suppression panels with abort, hold, delay — EN 12094-1 certified

Kentec · EN 12094-1
Gas & Flame Detection

Honeywell Analytics & ESP Safety

Fixed gas detectors, IR3 flame detectors, and controllers for hazardous areas — ATEX Zone 1 & 2.

📄

Sensepoint Pro Fixed Gas Detector

LEL, toxic, O₂ detection — Zone 1 and 2, ATEX/IECEx, 4-20mA + HART

Honeywell · ATEX · IECEx
📄

301C Gas Detection Controller

8-point centralized controller — relay outputs, event logging, ventilation interlock

Honeywell Analytics
📄

IR3 Triple Infrared Flame Detector

Response under 5 sec at 50m — ATEX Zone 1, IP66/67, solar blind technology

ESP Safety · ATEX · IECEx

Need a specific datasheet or submittal?
Our engineering team can provide full product submittals, compliance certificates, and technical documentation packages tailored to your project and consultant requirements. → Request Documentation

Need Technical Support?

Our engineers provide full submittal packages and technical documentation for any project.

Contact Engineering Team 📞 0150 732 0560
GuardexProTech